In addition to most of the features of LEVEL MASTER I, LEVEL
MASTER II has following striking features.
 |
Simultaneous real time level measurements in form bar
graph of 30 channels. Separate for both Vision and Aural
carriers. |
 |
Simultaneous display of Chan, Freq, Level and C/N in
accordance with CCIR Pal B/G with backlight. |
 |
User-friendly Menudriven features for ease of use. |
 |
108 channel X 200 location storage for printouts later
on. |
 |
Unique feature of Favorite channel recording and surfing
for the comfort of the user. s |
 |
Zoom feature to visually compare the levels more closely.
|
 |
User defined level correction for individual channels
to make it compatible with other meters in use. |
 |
Buzzer feature to have audible level tone in proportion
to level measured for hands-free operations. |
 |
Choice of measurement for channels below or above set
level to find out undesired signal levels, quickly. |
Option :
Software for pc interface. TELM 1.01
This software enables user to
1. remotely operate Level Master I or II , from serial port
of pc.
2. Data Acquisition from remote operation for later printing
and analysis os stored readouts.
3. Real time monitoring of all channels by visual indication
in form of bar graph or red colours to indicate the signal
levels of the channels, which are above or below the set value
of desired level.
This feature is very useful in the headend(control room).
For example if the signal level of any channel drops to zero
or very low level, it indicates the failure of that channel
or program by red colours indication, and without such an
arrangement, it is very difficult to know The failure of one
channel or program out of many channels (as many as 70 to
100 , now a days.) this feature helps to keep the customers
happy, because before the customers complain about any failure
of program, the owner of the catv network gets chance to correct
the failure.
Specification:
Frequency Range : 48MHz to 860MHz
Input Impedance : 75 Ohm
RFIN : F Connector
RF Level:
Level Range at RF IN : 30dbµV to 120bdµV
Level Measurement Accuracy : +/-1.5db
Resolution : 0.1db
Aural Carrier:
Tunable from : 53MHz to 870 MHz
Audio:
Audio heard through loudspeaker : 1W Aprox
AC VOLTMETER:
AC Voltage measurement Range : 0 to 100V AC
|